• ioLogik E2242 Specifications | |
• Inputs and Outputs | |
Configurable DIOs (by software) | 12 channels |
Analog Inputs | 4 channels |
Isolation | 3k VDC 2k Vrms |
• Digital Input | |
Sensor Type | Wet Contact (NPN PNP) and Dry Contact |
I/O Mode | DI Event Counter |
Dry Contact | • On: short to GND • Off: Open |
Wet Contact (DI to GND) | • On: 0 to 3 VDC • Off: 10 to 30 VDC |
Common Type | 6 points per COM |
Isolation | 3k VDC 2k Vrms |
Counter Frequency | 900 Hz |
Digital Filtering Time Interval | Software selectable |
• Digital Output | |
Type | Sink |
I/O Mode | DO Pulse Output |
Pulse Output Frequency | 1 kHz |
Over-Voltage Protection | 45 VDC |
Over-Current Protection | 2.6 A (4 channels @ 650 mA) |
Over-Temperature Shutdown | 175°C (min.) |
DIO Output Leakage Current | 4.0 mA @ 24 VDC |
Current Rating | 200 mA per channel |
• Analog Input | |
Type | Differential input |
Resolution | 16 bits |
I/O Mode | Voltage / Current (software selectable) |
Input Range | ±150 mV, 0 to 150 mV, ±500 mV, 0 to 500 mV, ±5 V, 0 to 5 V, ±10 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA |
Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -10 and 60°C ±0.5% FSR @ -40 and 75°C |
Sampling Rate | All channels: 32 samples/sec Per channel: 8 samples/sec Single channel: 100 samples/sec |
Input Impedance | 200 kilo-ohms ohms (min.) |
Built-in Resistor for Current Input | 120 ohms |
• Power Requirements | |
Input Voltage | 12 to 36 VDC |
Input Current | 178 mA @ 24 VDC |
• MTBF (mean time between failures) | |
Time | 204,391 hrs |
Standard | Telcordia SR332 |
• Common Specifications | |
• LAN | |
Ethernet | 1 10/100 Mbps RJ45 port |
Protection | 1.5 kV magnetic isolation |
Protocols | Modbus/TCP (slave), TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP |
• Serial | |
Interface | 1 RS-485-2w terminal block port |
Parity | None |
Data Bits | 8 |
Stop Bits | 1 |
Flow Control | None |
Baudrate | 1200 to 115200 bps |
Protocols | Modbus RTU (gateway) |
• Physical Characteristics | |
Wiring | I/O cable max. 14 AWG |
Dimensions | 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Weight | under 250 g (0.55 lb) |
Mounting | DIN-rail wall |
• Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6 |
Altitude | Up to 2000 m |
Note | Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 61000-6-2/6-4 |
EMI | CISPR 22, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m 1.4 GHz to 2 GHz: 3 V/m 2 GHz to 2.7 GHz: 1 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000- |
Green Product | RoHS, CRoHS, WEEE |
Note | Please check Moxa’s website for the most up-to-date certification status. |
• Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
MOXA, Smart Remote I/O
ioLogik E2242
Features and Benefits
-
Front-end intelligence with patented Click&Go control logic, up to 24 rules
-
Active communication with MX-AOPC UA Server
-
Save time and wiring cost with peer-to-peer communication
-
Supports SNMPv1/v2c/v3
-
Friendly configuration via web browser
-
Simplify I/O management with MXIO library for Windows Linux platforms
-
Wide operating temperature range of -40 to 75°C (-40 to 167°F)