Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters and upgrade firmware via USB Upgrade firmware through an RS-485 connection Wide operating temperature range: -40 to 85°C (-40 to 185°F)
Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters and upgrade firmware via USB Upgrade firmware through an RS-485 connection Wide operating temperature range: -40 to 85°C (-40 to 185°F)
Features and Benefits 8 analog input channels for millivolts (mV), voltage, and current signal with wire-off detection (at 4 to 20 mA) 2-channel analog outputs for voltage, current actuator control 16-bit resolution analog inputs, 12-bit resolution analog output Simplify I/O management with MXIO library on Windows Linux platform Firmware upgradable over RS-485
Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Using Active OPC Server software, SCADA systems can directly communicate with cellular devices hidden behind private IP addresses Active communication with Active OPC Server Automatically complement disconnection period data with DA-Center software Daisy chain up to 3 ioLogik E1200 units 3-in-1 RS-232/422/485 serial port for connecting…
Features and Benefits Direct input-to-output signal communication over IP High speed Peer-to-Peer I/O within 20 ms One physical alarm port for connectivity status Quick and easy utility and web-based settings Local alarm channel Remote alarm message Supports Modbus/TCP for remote monitoring Optional LCD module for easy configuration
Features and Benefits Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain topologies with bypass function Modular I/O for versatility, flexibility, and scalability Rugged and compact design for harsh environments Wide operating temperature: -40 to 75°C (-40 to 167°F) 3-in-1 RS-232/422/485 serial port Up to 32 GB…
Features and Benefits RM-1050-T: 10 channel-to-channel isolated DIs, 110 VDC, sink/source type RM-1602-T: 16 digital inputs, 24 VDC, sink/source type RM-2600-T: 16 digital outputs, 24 VDC, sink-type RM-3802-T: 8 analog inputs, 4 to 20 mA RM-3810-T: 8 analog inputs, 0 to 10 V KM-2430-T: 4-port unmanaged Ethernet switch module
Features and Benefits Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital input and analog input Supports 5 kHz sampling rate for analog input Pre-recording for analog input data logging Supports C/C++ or IEC 61131-3 programming languages Compliant with EN 50121-4, and EN 50155* specifications Robust and compact design for harsh environments…
Features and Benefits Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital input and analog input Supports 5 kHz sampling rate for analog input Pre-recording for analog input data logging Supports C/C++ IEC 61131-3 programming languages Compliant with EN 50121-3-2, EN 50121-4, and EN 50155 specifications Robust and compact design for harsh…
Features and Benefits 85M-1602-T: 16 digital inputs, 24 VDC, sink/source type 85M-2600-T: 16 digital outputs, 24 VDC, sink-type 85M-3800-T: 8 analog inputs, 4 to 20 mA 85M-3810-T: 8 analog inputs, 0 to 10 VDC 85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz 85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz 85M-5401-T: 4 serial ports (RS-232/422/485) 85M-6600-T:…
Features and Benefits Modular CPU/Power/Backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++ and IEC 61131-3 programming languages Compact, lightweight design Supports a redundant power module with dual-power inputs 24 to 110 V DI/O module and universal power input range module Complies with EN 50121-4 Complies with all EN 50155 mandatory test items*