CP-134U/CP-134U-I

Features and Benefits

  • Over 700 kbps data throughput for top performance
  • 921.6 kbps maximum baudrate for super fast data transmission
  • ADDC® provides automatic data direction control for RS-485 signals
  • 128-byte FIFO and on-chip H/W, S/W flow control
  • Compatible with 3.3/5 V PCI and PCI-X
  • Drivers provided for a broad selection of operating systems, including the latest Windows and Linux
  • Added bonus! Ports 1 and 2 support RS-232 and RS-422/485
  • Wide temperature model available for -40 to 85°C environments
• Hardware
Comm. Controller MU860 (16C550C compatible)
Bus 32-bit Universal PCI
Connector DB44 female
• Serial Interface
Number of Ports 4
Serial Standards 2 x RS-232/422/485, 2 x RS-422/485
Max. No. of Boards per PC 8
• Serial Line Protection
Electrical Isolation 2 kV (CP-134U-I configured for RS-422/485 only)
• Performance
Baudrate 50 bps to 921.6 kbps (supports non-standard baudrates)
• Serial Communication Parameters
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS, XON/XOFF, RTS Toggle (RS-232 only)
• Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND
RS-485-4w TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND
RS-485-2w Data+(B), Data-(A), GND
• Physical Characteristics
Dimensions CP-134U: 82.5 x 120 mm (3.24 x 4.72 in)
CP-134U-I: 115 x 120 mm (4.52 x 4.72 in)
• Driver Support
Windows Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows Server 2008 R2/2012/2012 R2/2016 (x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded
Linux Linux 2.4.x, 2.6.x, 3.x
Unix-like Systems QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD
Note Please refer to Moxa’s website for the latest driver support information.
• Environmental Limits
Operating Temperature Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Standards and Certifications
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class B
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
• MTBF (mean time between failures)
Time 480,209 hrs
Standard Telcordia (Bellcore) TR/SR
• Power Requirements
Input Current CP-134U: 180 mA @ 5 VDC
CP-134U-I: 850 mA @ 5 VDC
• Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty
Scroll to Top